Overall Rating Silver - expired
Overall Score 53.30
Liaison Emma Shipalesky
Submission Date June 19, 2015
Executive Letter Download

STARS v2.0

Northern Alberta Institute of Technology
OP-1: Greenhouse Gas Emissions

Status Score Responsible Party
Complete 1.40 / 10.00 Robert Akkerman
Acting Director
Maintenance and Operations
"---" indicates that no data was submitted for this field

Does the institution's GHG emissions inventory include all Scope 1 and Scope 2 GHG emissions?:
Yes

Does the institution's GHG emissions inventory include all Scope 3 GHG emissions from any of the following categories?:
Yes or No
Business travel No
Commuting No
Purchased goods and services Yes
Capital goods No
Fuel- and energy-related activities not included in Scope 1 or Scope 2 No
Waste generated in operations No

Does the institution's GHG emissions inventory include Scope 3 emissions from other categories?:
No

A brief description of the methodology and/or tool used to complete the GHG emissions inventory:

NAIT's Scope 1 and 2 GHG emissions inventory was completed with the assistance of the Canadian version of the "Clean Air-Cool Planet Campus Carbon Calculator”.

Scope 3 purchased goods and services include calculated GHG emissions from purchased paper and IT using data from manufacturer's websites.


Has the GHG emissions inventory been validated internally by personnel who are independent of the GHG accounting and reporting process and/or verified by an independent, external third party?:
No

A brief description of the internal and/or external verification process:
---

Scope 1 and Scope 2 GHG emissions::
Performance Year Baseline Year
Scope 1 GHG emissions from stationary combustion 13,178.89 Metric tons of CO2 equivalent 21,201.34 Metric tons of CO2 equivalent
Scope 1 GHG emissions from other sources 8,328.84 Metric tons of CO2 equivalent 2,752.39 Metric tons of CO2 equivalent
Scope 2 GHG emissions from purchased electricity 32,620.85 Metric tons of CO2 equivalent 44,236.64 Metric tons of CO2 equivalent
Scope 2 GHG emissions from other sources 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent

Figures needed to determine total carbon offsets::
Performance Year Baseline Year
Institution-catalyzed carbon offsets generated 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent
Carbon sequestration due to land that the institution manages specifically for sequestration 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent
Carbon storage from on-site composting 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent
Third-party verified carbon offsets purchased 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent

A brief description of the institution-catalyzed carbon offsets program:
---

A brief description of the carbon sequestration program and reporting protocol used:
---

A brief description of the composting and carbon storage program:
---

A brief description of the purchased carbon offsets, including third party verifier(s) and contract timeframes:
---

Figures needed to determine “Weighted Campus Users”::
Performance Year Baseline Year
Number of residential students 0 0
Number of residential employees 0 0
Number of in-patient hospital beds 0 0
Full-time equivalent enrollment 12,479 12,979.67
Full-time equivalent of employees 2,269.95 2,302.37
Full-time equivalent of distance education students 1,049.76 93.29

Start and end dates of the performance year and baseline year (or three-year periods):
Start Date End Date
Performance Year July 1, 2013 June 30, 2014
Baseline Year July 1, 2007 June 30, 2008

A brief description of when and why the GHG emissions baseline was adopted:
---

Gross floor area of building space, performance year:
297,357.05 Square meters

Floor area of energy intensive building space, performance year:
Floor Area
Laboratory space 1,653.80 Square meters
Healthcare space 1,878.55 Square meters
Other energy intensive space 28,439.53 Square meters

Scope 3 GHG emissions, performance year::
Emissions
Business travel ---
Commuting ---
Purchased goods and services 762.74 Metric tons of CO2 equivalent
Capital goods ---
Fuel- and energy-related activities not included in Scope 1 or Scope 2 ---
Waste generated in operations ---
Other categories (please specify below) ---

A brief description of the sources included in Scope 3 GHG emissions from "other categories":
---

A copy of the most recent GHG emissions inventory:
The website URL where the GHG emissions inventory is posted:
---

A brief description of the institution’s GHG emissions reduction initiatives, including efforts made during the previous three years:
---

Data source(s) and notes about the submission:
---

The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.