OP-5: Building Energy Consumption

Status Score Responsible Party
Complete 3.47 / 6.00 Les Williams
Associate Dir For Utilities & Energy Management
Utilities & Energy Management
"---" indicates that no data was submitted for this field

Figures needed to determine total building energy consumption:
Performance Year Baseline Year
Grid-purchased electricity 2,111,811 MMBtu 1,830,896 MMBtu
Electricity from on-site renewables 0 MMBtu 0 MMBtu
District steam/hot water (sourced from offsite) 0 MMBtu 0 MMBtu
Energy from all other sources (e.g., natural gas, fuel oil, propane/LPG, district chilled water, coal/coke, biomass) 2,612,511 MMBtu 4,909,874 MMBtu
Total 4,724,322 MMBtu 6,740,770 MMBtu

Start and end dates of the performance year and baseline year (or 3-year periods):
Start Date End Date
Performance Year Sept. 1, 2016 Aug. 31, 2017
Baseline Year Sept. 1, 2001 Aug. 31, 2002

A brief description of when and why the building energy consumption baseline was adopted (e.g. in sustainability plans and policies or in the context of other reporting obligations):

The baseline year of FY02 represents the start of a long journey to reduce the energy consumption of the campus. It represents the last year before many of the changes were implemented.


Gross floor area of building space:
Performance Year Baseline Year
Gross floor area of building space 24,233,204 Gross square feet 18,501,138 Gross square feet

Source-site ratio for grid-purchased electricity:
3.14

Total building energy consumption per unit of floor area:
Performance Year Baseline Year
Site energy 0.19 MMBtu per square foot 0.36 MMBtu per square foot
Source energy 0.38 MMBtu per square foot 0.58 MMBtu per square foot

Percentage reduction in total building energy consumption (source energy) per unit of floor area from baseline:
33.79

Degree days, performance year (base 65 °F / 18 °C):
Degree days (see help icon above)
Heating degree days 922 Degree-Days (°F)
Cooling degree days 3,159 Degree-Days (°F)

Floor area of energy intensive space, performance year:
Floor Area
Laboratory space 2,337,199 Square feet
Healthcare space 0 Square feet
Other energy intensive space

EUI-adjusted floor area, performance year:
31,328,040 Gross square feet

Building energy consumption (site energy) per unit of EUI-adjusted floor area per degree day, performance year:
36.95 Btu / GSF / Degree-Day (°F)

Documentation (e.g. spreadsheet or utility records) to support the performance year energy consumption figures reported above:
---

A brief description of the institution's initiatives to shift individual attitudes and practices in regard to energy efficiency (e.g. outreach and education efforts):

Texas A&M has a long history of trying to shape the attitudes of faculty, staff and stusdents attitudes. The Energy Stewardship program continues its outreach to educate the campus constituents about energy efficiency. The newly formed Energy Performance Improvement or EPI program takes the Energy Stewardship program to the next level by engaging and incentivizing building occupants to take action to reduce energy consumption. The program is projected to cost avoid over $450k during the 12 month pilot period.


A brief description of energy use standards and controls employed by the institution (e.g. building temperature standards, occupancy and vacancy sensors):

Texas A&M University has adopted a cooling standard of 70 degrees F and a heating standard of 65 degrees F across the campus. More importantly, when buildings or space is not occupied, the standard automatically resets to the unoccupied standard of 85 for cooling and 50 for heating.


A brief description of Light Emitting Diode (LED) lighting and other energy-efficient lighting strategies employed by the institution:

During FY17, Texas A&M upgraded all high pressure sodium and lower efficiency metal halide exterior lighting fixtures to LED.


A brief description of passive solar heating, geothermal systems, and related strategies employed by the institution:
---

A brief description of co-generation employed by the institution, e.g. combined heat and power (CHP):

Texas A&M University has installed a $73.25 million combined heat and power upgrade that will supply over 45 MW of highly efficient power and steam generation to serve the campus. This system replaces an existing CHP system and achieves efficiencies in excess of 80%.


A brief description of the institution's initiatives to replace energy-consuming appliances, equipment and systems with high efficiency alternatives (e.g. building re-commissioning or retrofit programs):

The campus created the first Energy Stewardship program in FY11 and currently has a fully staffed team of 6 Energy Stewards and a Supervisor. This team is responsible for closely monitoring and managing the campus energy consumption on a daily basis. This team relies on the data from the campus' comprehensive metering system to measure the energy consumption of the buildings and to make changes when necessary.


The website URL where information about the programs or initiatives is available:
Additional documentation to support the submission:
---

Data source(s) and notes about the submission:
---

The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.