OP-5: Building Energy Consumption

Status Score Responsible Party
Complete 3.37 / 6.00 Ron Crowl
Associate Vice President for Planning and Program Implementation, Chief Planning Officer
Business Office
"---" indicates that no data was submitted for this field

Figures needed to determine total building energy consumption:
Performance Year Baseline Year
Grid-purchased electricity 55,279.20 MMBtu 50,688.30 MMBtu
Electricity from on-site renewables 137.60 MMBtu 0 MMBtu
District steam/hot water (sourced from offsite) 0 MMBtu 0 MMBtu
Energy from all other sources (e.g., natural gas, fuel oil, propane/LPG, district chilled water, coal/coke, biomass) 101,872 MMBtu 91,461 MMBtu
Total 157,288.80 MMBtu 142,149.30 MMBtu

Start and end dates of the performance year and baseline year (or 3-year periods):
Start Date End Date
Performance Year July 1, 2019 June 30, 2020
Baseline Year July 1, 2004 June 30, 2005

A brief description of when and why the building energy consumption baseline was adopted (e.g. in sustainability plans and policies or in the context of other reporting obligations):

STARS version 1.0 used as baseline.


Gross floor area of building space:
Performance Year Baseline Year
Gross floor area of building space 1,358,311 Gross square feet 1,041,210 Gross square feet

Source-site ratio for grid-purchased electricity:
3.14

Total building energy consumption per unit of floor area:
Performance Year Baseline Year
Site energy 0.12 MMBtu per square foot 0.14 MMBtu per square foot
Source energy 0.20 MMBtu per square foot 0.24 MMBtu per square foot

Percentage reduction in total building energy consumption (source energy) per unit of floor area from baseline:
15.71

Degree days, performance year (base 65 °F / 18 °C):
Degree days (see help icon above)
Heating degree days 5,277 Degree-Days (°F)
Cooling degree days 1,037 Degree-Days (°F)

Floor area of energy intensive space, performance year:
Floor Area
Laboratory space 23,652 Square feet
Healthcare space 0 Square feet
Other energy intensive space

EUI-adjusted floor area, performance year:
1,414,445 Gross square feet

Building energy consumption (site energy) per unit of EUI-adjusted floor area per degree day, performance year:
17.61 Btu / GSF / Degree-Day (°F)

Documentation (e.g. spreadsheet or utility records) to support the performance year energy consumption figures reported above:
---

A brief description of the institution's initiatives to shift individual attitudes and practices in regard to energy efficiency (e.g. outreach and education efforts):

Sharing of Green Revolving Fund Projects/outcomes, solicitation of ideas from all campus users. Programs/events about energy efficiency - impacts on Climate Change (24-hours of Reality: Truth in Action - Climate Reality Project). Sustainable Living programs.


A brief description of energy use standards and controls employed by the institution (e.g. building temperature standards, occupancy and vacancy sensors):

Johnson Controls Metasys


A brief description of Light Emitting Diode (LED) lighting and other energy-efficient lighting strategies employed by the institution:

954,772 sq. ft. of our total campus footprint of 1.4 million sq. ft. has been converted to LED - through Green Revolving Fund and other incentives offered through electric company.


A brief description of passive solar heating, geothermal systems, and related strategies employed by the institution:

Geothermal is used in the Gartner Welcome Center.


A brief description of co-generation employed by the institution, e.g. combined heat and power (CHP):

None


A brief description of the institution's initiatives to replace energy-consuming appliances, equipment and systems with high efficiency alternatives (e.g. building re-commissioning or retrofit programs):

LED retro-fits, Fume Hood conversions, Motion Sensors, Programmable Thermostats.


The website URL where information about the programs or initiatives is available:
---

Additional documentation to support the submission:
---

Data source(s) and notes about the submission:

Information from Ron Crowl, through GHG Report 2020.

Onsite Renewable Generation from MAAC Solar Panel's taken from Sunny Portal site and additional estimate for the 1-KW system on HPCC (based on "A solar system that is installed on a south-facing 30-degree pitch roof Ohio will generate 1,150kWh of peak DC (direct current) capacity per year per 1kW in Ohio." from https://www.solarreviews.com/solar-panels/ohio)

Heating/Cooling Degree Days - https://portfoliomanager.energystar.gov/pm/degreeDaysCalculator
Results
Weather Station ID:
725210
Weather Station Name:
AKRON/AKRON-CANTON

Time Period:
July 01, 2019 - June 30, 2020
Annual HDD:
5277 °F
Annual CDD:
1037 °F


Information from Ron Crowl, through GHG Report 2020.

Onsite Renewable Generation from MAAC Solar Panel's taken from Sunny Portal site and additional estimate for the 1-KW system on HPCC (based on "A solar system that is installed on a south-facing 30-degree pitch roof Ohio will generate 1,150kWh of peak DC (direct current) capacity per year per 1kW in Ohio." from https://www.solarreviews.com/solar-panels/ohio)

Heating/Cooling Degree Days - https://portfoliomanager.energystar.gov/pm/degreeDaysCalculator
Results
Weather Station ID:
725210
Weather Station Name:
AKRON/AKRON-CANTON

Time Period:
July 01, 2019 - June 30, 2020
Annual HDD:
5277 °F
Annual CDD:
1037 °F

The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.