Overall Rating Gold
Overall Score 67.28
Liaison Geory Kurtzhals
Submission Date Jan. 4, 2022

STARS v2.2

University of Notre Dame
OP-1: Emissions Inventory and Disclosure

Status Score Responsible Party
Complete 2.04 / 3.00 Geory Kurtzhals
Sr. Director
Office of Sustainability
"---" indicates that no data was submitted for this field

Has the institution conducted a GHG emissions inventory within the previous three years that includes all Scope 1 and 2 emissions? :
Yes

A copy of the most recent GHG emissions inventory:
A brief description of the methodology and/or tool used to complete the GHG emissions inventory:

The University has its own permitted power plant and reports pursuant to that permit. The attached file is the greenhouse gas reporting to the EPA. It covers Scope 1 emissions on campus for the fiscal year 2020.
The Scope 2 emissions are calculated based upon our purchased power and a conversion given by the local power company for MWh to tons CO2.


Has the GHG emissions inventory been validated internally by personnel who are independent of the GHG accounting and reporting process and/or verified by an independent, external third party?:
Yes

A brief description of the GHG inventory verification process:

The Office of Sustainability independently calculates and verifies the values from the Utilities Office and local utility provider Indiana Michigan Power.

For scope 2 emissions a conversion factor is provided by our local utility, 788 lbs of CO2 / mWH. For FY 2020, our scope 2 emissions were 22,426.1466 metric tons of CO2.


Documentation to support the GHG inventory verification process:
---

Gross Scope 1 GHG emissions, performance year:
Weight in MTCO2e
Stationary combustion 144,161 Metric tons of CO2 equivalent
Other sources (mobile combustion, process emissions, fugitive emissions) 0 Metric tons of CO2 equivalent

Total gross Scope 1 GHG emissions, performance year:
144,161 Metric tons of CO2 equivalent

Gross Scope 2 GHG emissions, performance year (market-based):
Weight in MTCO2e
Imported electricity 22,426.15 Metric tons of CO2 equivalent
Imported thermal energy 0 Metric tons of CO2 equivalent

Total gross Scope 2 GHG emissions, performance year:
22,426.15 Metric tons of CO2 equivalent

Gross GHG emissions from biogenic sources, performance year:
0 Metric tons of CO2 equivalent

Does the GHG emissions inventory include Scope 3 emissions from the following sources?:
Yes or No Weight in MTCO2e
Business travel No ---
Commuting No ---
Purchased goods and services No ---
Capital goods No ---
Fuel- and energy-related activities not included in Scope 1 or Scope 2 No ---
Waste generated in operations No ---
Other sources No ---

Total Scope 3 GHG emissions, performance year:
0 Metric tons of CO2 equivalent

A brief description of how the institution accounted for its Scope 3 emissions:
---

Has the institution completed an inventory within the previous three years to quantify its air pollutant emissions?:
Yes

Annual weight of emissions for::
Weight of Emissions
Nitrogen oxides (NOx) 216.47 Tons
Sulfur oxides (SOx) 323.70 Tons
Carbon monoxide (CO) 90.20 Tons
Particulate matter (PM) 19.43 Tons
Ozone (O3) 0 Tons
Lead (Pb) 0.00 Tons
Hazardous air pollutants (HAPs) 8.78 Tons
Ozone-depleting compounds (ODCs) 0 Tons
Other standard categories of air emissions identified in permits and/or regulations 0 Tons

Do the air pollutant emissions figures provided include the following sources?:
Yes or No
Major stationary sources Yes
Area sources No
Mobile sources No
Commuting No
Off-site electricity production No

A brief description of the methodology(ies) the institution used to complete its air emissions inventory:

The values for emissions come from our permitted stationary sources - six boilers and five generators for the July 1, 2019 though June 30, 2020.


Gross Scope 2 GHG emissions from purchased electricity (location-based):
---

Gross Scope 2 GHG emissions from imported thermal energy (location-based) :
---

Website URL where information about the institution’s emissions inventories is available:
---

Additional documentation to support the submission:
---

Data source(s) and notes about the submission:
---

The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.